The original FIRM-FILL® Gypsum Concrete floor underlayment is designed for use in multi-family housing to satisfy acoustical ratings and fire codes. With excellent STC and IIC ratings as well as over 86 UL listings, FIRM-FILL® Gypsum Concrete floor underlayment is an excellent choice for jobs needing compressive strengths up to 2000 psi.
FIRM-FILL® Gypsum Concrete Floor Underlayment Features and Benefits
·Flattens subfloors
·Provides excellent STC (sound transmission) and IIC (impact isolation) ratings
·Possesses over 86 UL listings
·Lightweight and crack resistant
·Easily installed; over 40,000 square feet can be installed per day
·Quick drying; can be walked on in 90 minutes
·Expert application; installed only by trained, Licensed Applicators
·Approvals from ICC-ES and HUD
Meets ASTM F2419, Standard Practice for the Installation of Thick Poured Gypsum Concrete Underlayments and the Preparation of the Surface to Receive Resilient Flooring
| Technical Data |
Properties |
ASTM |
| Weight |
7 psf at 3/4" |
C-472 |
| Thickness |
3/4" (19mm) (minimum over wood) to 3 1/2" (89mm) |
|
| Compressive Strength |
1200 - 2000 psi |
C-472 |
| Thermal Performance |
K-value of 2.45 Btu; R-value of 0.41 ft2.h. oF/Btu |
C-177-76 |
| Fire Hazard Classification |
Flamespread index 0; Fuel Contribution 0; Smoke Density 0 |
E-84 |
| Patty Size |
8" (203mm) plus or minus 1/2" (13mm) in diameter |
|
| Sand |
1/8" (3mm) or less washed plaster or masonry sand |
E-11 |
FIRM-FILL® Gypsum Concrete